MagnaClean HP™ - Effective Heat Pump Protection
Low
temperature heating systems, such as heat pumps, are the perfect breeding ground for bacterial
growth. If managed incorrectly, bacterial growth can clog up the system, reduce efficiency and ultimately cause breakdowns down the line.
MagnaClean HP is specifically designed to protect
heat pumps from both magnetic and non-magnetic contaminants, meaning you can keep your heat pumps running as efficiently as possible, for as long as possible.
Thanks to its high-quality build, powerful magnet, stainless steel gauze and non-blocking design, you can rest assured that MagnaClean HP will efficiently protect your heat pump and will stand the test of time.
Homeowner benefits
- Protects your heat pump system from both magnetic and non-magnetic debris.
- Save up to 7% per year on your gas usage*.
- Immediate ongoing system protection.
- Extended system life of up to 7 years.
- Reduces CO2 emissions by up to 250kg per year.
- 10-year warranty when registered within 30 days of installation.
*Based on independent research in the UK.
Technical Specifications
Canister and Lid
- Material: Glass reinforced nylon
- Fluid capacity: 930ml
- Inlet diameter: 1" at valve
- Outlet diameter: 1" at valve
- Thread: Pressure thread
- Flow configuration: Directional inlet on bottom port
- Main lid seal: EPDM
Valve to canister: EPDM
Magnet
- Housing: Stainless steel
- Length: 150 mm
- Diameter: 19 mm
Valves
- Body material: Nickel-plated brass
- Seal material: long-life PTFE ball seals
- O ring material: EPDM
- Valve inlet/outlet: 22mm
Specifications
- Internal water operating temperature: 3°C to 95°C
- Maximum working pressure: 6 bar
- Maximum flow rate: 80 L/min (5m3/h)
Drain port
- Drain plug material: Nickel-plated brass
- Drain plug thread: M8
- Seals: EPDM
Bleed Valve
- Body material: Nickel-plated brass
- Screw: Nickel-plated brass
- Thread interface: M6
- Seals: EPDM
Servicing Clearance
- Air vent (top): 50 mm
- Drain Plug (bottom): 50 mm
Size/dimensions (product installation)
- Height: 250.5mm
- Width at lid: 115mm
Installation and servicing guide
Maintain peak performance
Whether you’re fitting a MagnaClean HP™ on a brand-new heat pump installation or
retrofitting it on an existing one, get the installation right to
give the heat pump the best protection possible. To help keep the filter
performing at peak efficiency, just like it was the day it was fitted, service it on an annual basis. Download our guides for detailed information.
- Always follow the electrical and safety standards when installing a filter.
- It is recommended that the filter is installed by a qualified heating engineer.
- MagnaClean HP must be installed indoors and is not suitable for external use.
- MagnaClean HP should ideally be fitted in-line on the return pipe. Alternative sitings can be located when the return pipe is not available.
Learn more about magnetic filters
What is sludge and how does it affect your heating system?
Sludge is the number one cause of central heating breakdown.
Breakdowns cost the UK over £700m a year in unexpected bills.
Sludge, also known as iron oxide or magnetite builds up within your heating
system and can clog up your pipes and cause damage to
expensive parts.
ADEY is here to stop this.

RELATED PRODUCT
Prevent biological build-up with MC10+ Biocide
With a dual biocide formulation, MC10+ tackles algae and biological contamination with ease. Extra concentrated, containing two active ingredients, it’s more effective than single biocide products when it comes to preventing the problems that arise in underfloor heating.
View productMagnaClean HP™ - Effective Heat Pump Protection
Low
temperature heating systems, such as heat pumps, are the perfect breeding ground for bacterial
growth. If managed incorrectly, bacterial growth can clog up the system, reduce efficiency and ultimately cause breakdowns down the line.
MagnaClean HP is specifically designed to protect heat pumps from both magnetic and non-magnetic contaminants, meaning you can keep your heat pumps running as efficiently as possible, for as long as possible.
Thanks to its high-quality build, powerful magnet, stainless steel gauze and non-blocking design, you can rest assured that MagnaClean HP will efficiently protect your heat pump and will stand the test of time.
Homeowner Benefits
- Protects your heat pump system from both magnetic and non-magnetic debris.
- Save up to 7% per year on your gas usage*.
- Immediate ongoing system protection with dedicated magnetic and non-magnetic capture .
- Extended system life of up to 7 years
- Reduces CO2 emissions by up to 250kg per year.
- 10-year warranty when registered within 30 days of installation.
*Based on independent research in the UK.

Technical Specifications
Technical Specifications
Internal
water operating temperature: 3°C to 95°C
Maximum
working pressure: 6 bar
Maximum flow rate: 80 L/min (5m3/h)
Canister and Lid
Material: Glass reinforced nylon
Fluid capacity: 930ml
Inlet diameter: 1" at valve
Outlet diameter: 1" at valve
Thread: Pressure thread
Flow configuration: Directional inlet on bottom port
Main lid seal: EPDM
Valve to canister: EPDM
Magnet
Housing: Stainless steel
Length: 150mm
Diameter: 19mm
Seal Valves
Body
material: Nickel-plated brass
Seal
material: Long-life PTFE ball seals
O ring
material: EPDM
Valve inlet/outlet: 1" BSPP and 28mm compression
Bleed Valve
Body material: Nickel-plated brass
Screw: Nickel-plated brass
Thread interface: M6
Seals: EPDM
Drain Port
Drain plug material: Nickel-plated brass
Drain plug thread: M8
Seals: EPDM
Servicing Clearance
Air vent
(top): 50 mm
Drain Plug (bottom): 50 mm
Size dimensions
Height: 250.5mm
Width at lid: 115mm
Installation & Servicing
Maintain peak performance
Whether you’re fitting a MagnaClean HP™ on a brand-new
heat pump installation or retrofitting it on an existing one, get the
installation right to give the heat pump the best protection possible. To help
keep the filter performing at peak efficiency, just like it was the day it was
fitted, service it on an annual basis. Download our guides for detailed
information.
- Always follow the electrical and safety standards when installing a
filter.
- It is recommended that the filter is installed by a qualified heating engineer.
- MagnaClean HP must be installed indoors and is
not suitable for external use.
- MagnaClean HP should ideally be fitted in-line on the return pipe. Alternative sitings can be located when the return pipe is not available.
Learn more about magnetic filters

What is sludge and how does it affect your heating system?
Sludge is the number one cause of central heating breakdown.
Breakdowns cost the UK over £700m a year in unexpected bills.
Sludge, also known as iron oxide or magnetite builds up within your heating
system and can clog up your pipes and cause damage to
expensive parts.
ADEY is here to stop this.
RELATED PRODUCT

Prevent biological build-up with MC10+ Biocide
With a dual biocide formulation, MC10+ tackles algae and biological contamination with ease. Extra concentrated, containing two active ingredients, it’s more effective than single biocide products when it comes to preventing the problems that arise in underfloor heating.
View ProductHeat Pumps: The Future of Heating in the UK?
As the UK government aims to reach its target of net-zero emissions by 2050, renewable energy sources are becoming more important than ever and will soon become the norm within the heating industry. But what does this mean for you?
Read our article to find out
Help & Support
Click to view our Customer Support,
Savings Calculator and FAQs


Tool
Product
Selector
Get straight to the
products you need in a
few clicks.

Tool
Find a
Rep
Discover who your local Business Support Manager is.

Tool
Find a
Stockist
Enter your postcode to find your nearest merchant .

Helpful Tools
ADEY’s got some handy tools to help you protect your central heating system…

Product
Selector
Get straight to the products you need in a few clicks.

Find a
Rep
Discover who your local Business Support Manager is.


Need
Spares?
You can buy spares parts direct from us on our ADEY Spares site.